Development of modified micro computed tomography system for nondestructive testing


Ian Yulianti, - (2019) Development of modified micro computed tomography system for nondestructive testing. Journal of Physics: Conference Series.

[thumbnail of Article] PDF (Article)
Download (781kB)
[thumbnail of Turnitin] PDF (Turnitin)
Download (2MB)

Abstract

This paper presents a development of micro Computed Tomography (microCT) imaging system based on digital radiography. The system comprises stepper motor, CMOS detector, microcontroller and digital radiography unit. Scanning process was done by rotating the object while exposing its cross- sectional surface to X-ray radiation. The object was rotated by using stepper motor controlled by microcontroller. The normal of cross-sectional surface taken as the rotation axis. Therefore, a number of 2D image slices were obtained by rotating the object from 0o to 360o . The 2D image slices were then reconstructed to form 3D image using computer. By using the proposed microCT, analysis of surface and internal of the object can be done in 3D image and 2D image (slice) for nondestructive testing (NDT) application.

Item Type: Article
Subjects: Q Science > QC Physics
Fakultas: Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika, S1
Depositing User: Setyarini UPT Perpus
Date Deposited: 12 Apr 2023 07:51
Last Modified: 12 Apr 2023 08:16
URI: http://lib.unnes.ac.id/id/eprint/57120

Actions (login required)

View Item View Item