EMULSION LIQUID MEMBRANE FOR HEAVY METALS REMOVAL: EMULSION BREAKING STUDY
Adhi Kusumastuti, FT Tata Busana EMULSION LIQUID MEMBRANE FOR HEAVY METALS REMOVAL: EMULSION BREAKING STUDY. Jurnal Teknologi.
PDF
Download (438kB) |
|
PDF (Uji Turnitin)
Download (2MB) |
Abstract
Emulsion liquid membrane (ELM) method has been widely applied in the separation process as the alternative of liquid/liquid extraction. This study compared the application of microwave, ultrasonic probe, and centrifuge in breaking the used emulsion. Demulsification efficiency was investigated in term of water content in the membrane phase solution before and after demulsification. The results showed that the use of microwave to break the used emulsion provided demulsification efficiency of 98.10%, while application of ultrasonic probe was able to break emulsion at efficiency of 98.45%. In the meantime, demulsification efficiency of almost 97% was achieved when employing centrifuge at centrifugation speed of 3000 rpm. Considering the energy consumption, it is recommended to apply microwave irradiation for emulsion breaking. It could save energy up to 97% and 99% compared to that of ultrasonic probe and centrifuge, respectively.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Emulsion liquid membrane, heavy metals, removal, emulsion breaking, demulsification |
Subjects: | T Technology > TY Pendidikan Kesejahteraan Keluarga > TY3 Tata Busana S1 |
Fakultas: | Fakultas Teknik > Pendidikan Tata Busana, S1 |
Depositing User: | dina nurcahyani perpus |
Date Deposited: | 14 Dec 2022 07:19 |
Last Modified: | 19 Dec 2022 05:42 |
URI: | http://lib.unnes.ac.id/id/eprint/54220 |
Actions (login required)
View Item |