AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA SISTEM PENGKONDISIAN UDARA DI HOTEL SANTIKA PREMIERE SEMARANG


Agus Rianto , 5350403063 (2007) AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA SISTEM PENGKONDISIAN UDARA DI HOTEL SANTIKA PREMIERE SEMARANG. Under Graduates thesis, Universitas Negeri Semarang.

[thumbnail of AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA SISTEM PENGKONDISIAN UDARA DI HOTEL SANTIKA PREMIERE SEMARANG]
Preview
PDF (AUDIT ENERGI DAN ANALISIS PELUANG PENGHEMATAN KONSUMSI ENERGI PADA SISTEM PENGKONDISIAN UDARA DI HOTEL SANTIKA PREMIERE SEMARANG) - Published Version
Download (2MB) | Preview

Abstract

Energi listrik sangat penting dalam indrustri perhotelan. Hal ini sangat menunjang dalam operasional di Hotel Santika Premiere Semarang. Peralatan seperti pengkondisian udara merupakan peralatan yang banyak mengkonsumsi energi listrik. Hampir sekitar 60% penggunaan energi listrik digunakan untuk sistem pengkondisian udara. Hal ini merupakan suatu pemborosan energi. U ntuk menanggulangi masalah tersebut dilakukan efisiensi energi. Salah satu metode yang sekarang dipakai untuk mengefisienkan pemakaian energi adalah konservasi energi. Konservasi energi adalah peningkatan efisiensi energi yang digunakan atau proses penghematan energi. Dalam proses ini meliputi adanya audit energi yaitu suatu metode untuk menghitung tingkat konsumsi energi suatu gedung atau bangunan. Pada audit energi di Hotel Santika Premiere terlihat bahwa konsumsi enrgi listrik adalah yang paling dominan. Sebagaimana menurut persenstasi energi yang dipakai, komposisi energi listrik dapat mencapai 91% dari total konsumsi energi, sedangkan solar 6%, air 3%. Berdasarkan audit awal terlihat bahwa IKE (Intesitas Konsusi Energi) di Hotel Santika Premiere mencapai 341,683 kWH / m2 year lebih besar dari standar ASEANUSAID yaitu 300 kWH / m2 year. Berdasarkan hasil audit energi rinci, diperoleh harga IKE untuk energi listrik adalah sebesar 403,08 kWH / m2 year. Peluang Hemat Energi (PHE) pada audit energi ini adalah dengan pembersihan pada unit FCU yaitu meliputi pembersihan saringan udara (filter), sudu kipas, sirip (fin) evaporator dan kisi keluaran (grill) pada unit-unit FCU. Peluang Hemat Energi (PHE) yang kedua adalah dengan Mengatur (setup) temperatur air keluar (Leaving Chilled Water Temperature = LCWT) pada chiller. D ari hasil perhitungan IKE setelah penerapan PHE, didapati nilai yang masih cukup tinggi sehingga usaha penghematan masih harus dilakukan. --------------------------------------------------------> E lectric Energy is very important in Hotel industry. It support in Hotel Santika Premiere’s operation. This equipment for instance air conditioner consume electric energy. Electric energy of air conditioner consuming reach 60%. It is one of energy extravagance. To resolve that problem efficiency energy used. One of method efficiency energy is conservation energy. Conservation energy is efficiency energy raising or energy proceed. In this process, audit energy is one of method to calculate Intensity Consume Energy (ICE) at one particular building. In energy audit Hotel Santika Premiere Semarang seen that electrics energy consumption is most dominant. As according to percentage of energy consumed composition in this fair matter hotel where electrics can reach 91 % from total energy consumption, Solar 6 %, Water 3%. A s according Preliminary Energy Audit seem that Hotel Santika Premiere Semarang’s Intensity Consume Energy (ICE) can reach 341,683 kWH/m2 year is bigger than standard ASEAN-USAID standard reach 300 kWH/m2 year. As according Detailed Energy Audit, Intensity Consume Energy (ICE) is 403,08 kWH/m2 year. Economical Opportunity of Energy (EOE) in this audit energy is cleaning FCU. It is consist of cleaning filter, fan, evaporator fin, and grill. Second Economical Opportunity of Energy (EOE) is setting Leaving Chilled Water Temperature (LCWT) in chiller. F rom result of calculation of IKE after implementation PHE, its value still high enough so that the effort thrift still must be done

Item Type: Thesis (Under Graduates)
Uncontrolled Keywords: Air Conditioner (AC); Hemat Energi; perhotelan
Subjects: T Technology > TK Electrical and Electronic Engineering